Compressed air leaks: how much electricity is your plant losing each year, and how to estimate it

Energy · 3 min read · Updated 13 Nov 2026 · ATS Vietnam engineering team

The air compressor is one of the most power-hungry pieces of equipment in many plants, and part of that electricity goes straight into the air through leaks nobody hears. US Department of Energy (DOE) material says that in plants without good maintenance, leaks can account for about 20–30% of compressor output. This article helps you estimate how much your plant is losing.

A quick self-check in 30 minutes

Do it when the plant is idle (lunch break, end of shift), when all air-using machines are off but the compressor is still running:

  • Time the compressor: if nobody is using air but the compressor still runs loaded, air is escaping somewhere.
  • Measure the ratio: record loaded time and unloaded time over 10–15 minutes. Leak rate ≈ loaded time ÷ total time. For example, loaded 4 minutes out of 10 → leaks of about 40% of compressor capacity.
  • Or watch the pressure gauge: shut off the compressor and see whether pressure in the tank and pipeline drops fast or slowly. A fast drop means heavy leaks.

This method only tells you whether leaks are heavy or light, not where they are.

Formula to estimate lost electricity cost

Annual loss ≈ Compressor power (kW) × Leak rate × Operating hours per year × Electricity price

ExampleValue
Screw compressor37 kW
Leak rate measured when the plant is idle25%
Operating hours per year (2 shifts, 6 days)about 5,000 hours
Average electricity price (replace with the real price on your bill)VND 2,000/kWh
Electricity lost per year37 × 25% × 5,000 × 2,000 ≈ VND 92 million

This is a rough estimate, usually a little high because the compressor does not always run at full load. But it is enough to tell whether a leak survey is worth doing.

The most common leak spots

  • Quick couplings and hose fittings at blow guns and hand tools.
  • Filters, regulators and lubricators (FRL units) in front of machines.
  • Drain valves on the tank and filters: automatic valves stuck open, or manual valves left slightly open "to be safe".
  • Cylinders and solenoid valves with worn seals.
  • Hoses that are cracked, crushed or overstretched.
  • Air used for the wrong job: blowing off dust, cooling with compressed air left open all the time. Not a leak, but it costs just as much as one.

When to survey with an ultrasonic detector

Air leaks give off high-frequency sound that the human ear cannot hear over plant noise. An ultrasonic detector picks up that sound while the plant is running and pinpoints each spot, even very small ones. Survey when:

  • The quick self-check shows a leak rate of about 15% or more.
  • The compressor is about 15 kW or larger and runs the whole shift.
  • Pressure at the end of the line often drops and the compressor pressure has to be raised to compensate.

After repair: keeping leaks from coming back

  1. Tag and number every leak, remove the tag once fixed, so you know how many remain.
  2. Lower the compressor pressure to the lowest level at which machines still run well: the higher the pressure, the more leakage.
  3. Re-survey every 6 months; assign one person to be responsible.

How ATS does this

ATS surveys with an ultrasonic detector while the plant is running, tags each leak and calculates lost electricity at the plant's real electricity price. If the estimated annual loss is lower than the survey fee, ATS does not charge the survey fee. See the compressed air leak detection service.

For reference only. Work on energised panels requires qualified, safety-trained personnel. ATS inspections do not replace the statutory inspection required for equipment subject to it under Vietnamese regulations.

Frequently asked questions

Are compressed air leaks dangerous or just a waste of electricity?

Mainly a waste of electricity. But heavy leaks cause pressure drop at the end of the pipeline, air-powered machines run weakly or fault, and the compressor has to run more and wears out sooner.

Is listening by ear enough?

It only finds large leaks when the plant is quiet. When machines are running, the hissing is drowned out. An ultrasonic detector hears small leaks even during production hours.

How long after repair do leaks come back?

New leaks keep appearing due to vibration, aging hoses and fittings being taken apart and reassembled. It is usually best to re-survey every 6 months, and set the compressor pressure at the lowest level that is still enough.